Description: Blow-Fill-Seal Machine
Complete with Some Spares - For Complete Spares List Please Contact Us

  • Various Mould Segments will be supplied with the machine, but without any product coding.
  • NEU Engineering Polyloader.
  • Equiptec ES100 Dryer.
  • Hydraulik 132013-051-0020 Hydraulic Pack.
  • Vacuum Pump Assembly
  • Operational and Maintenance documentation

 

Machine Data:

  • Extruder Ø: 45 mm (9 D)
  • Extruder motor: 32kW
  • Plastic granulate used: LDPE
  • Plasticizing capacity for plastic granulate: 65 kg/h
  • Steam: 2.5 bar; purity <1 µm
  • Consumption for preparation: 40 kg/h
  • Consumption for production: 15 kg/h
  • Cooling water: 12 ºC, 4 bar; <55 µm / 12 ºdH
  • Consumption: 2 m3/h

 

Ambient Conditions:

  • Temperature (machine):
  • Storage temperature: 15-30 ºC
  • Operating temperature: 15-30 ºC
  • Air moisture: 40-80%

 

Services Specifications:
Electrical:

  • Enclosure type: IP54
  • Supply Voltage: 3 Phase 400 V N, PE
  • Frequency: 50 HZ
  • Current: 120 A
  • Control Voltage: 24 V DC
  • Main Fuse: 125 A
  • Rated Power Consumption: 80 kVA

 

Pneumatic:

  • Air Pressure: 8 bar
  • Max. Consumption: 350 l/min

 

Hydraulic:

  • Pressure: max. 160 bar
  • Hydraulic motor: 11 kW

 

Emissions:

  • Noise: 77 dB(A)

 

Dimensions & Weight:

  • Weight: approx. 7000kgs
  • Length: approx. 3150mm
  • Width: approx. 2825mm
  • Height: approx. 2800mm

 

The machine was last being used to fill sterile pharmaceutical product into unit dose vials, running 1, 2 & 4ml Unit Dose Vials at 11000 UDV’s per hour.
Quantity: Contact for Availability
Serial number: 3051 76/654.97
Date of manufacture: 1998

Click Here To Download:
Corporate Overview Brochure
Go-Optimize Suite Of Services Brochure
Pharmaceutical Asset Management Software System: AssetZone® Brochure
Auction And Sales Services Brochure
Exchange Program Brochure
Valuation Services Brochure